{"id":4294,"date":"2026-04-14T13:54:03","date_gmt":"2026-04-14T11:54:03","guid":{"rendered":"https:\/\/sklep.geoscanners.pl\/produkt\/klema-indukcyjna-do-generatora-leica-de100\/"},"modified":"2026-09-22T09:52:51","modified_gmt":"2026-09-22T07:52:51","slug":"leica-de100-signal-clamp","status":"publish","type":"product","link":"https:\/\/sklep.geoscanners.pl\/en\/produkt\/klema-indukcyjna-do-generatora-leica-de100\/","title":{"rendered":"Inductive clamp for the Leica DE100 signal transmitter"},"content":{"rendered":"<p>The clamp (inductive coil) is designed to couple a signal from the DE100 transmitter onto a conductor, cable or utility where a direct galvanic connection using crocodile clips is difficult or impossible. The system documentation describes its use both as a transmitter clamp (to apply a signal) and as a locator clamp (to identify a specific cable in a bundle). <\/p>\n<p>Parameters<\/p>\n<p>Part number (Leica): 1005583.<br \/>\nCable length: 5 m.<br \/>\nClamp dimensions and weight (Signal clamp specifications): A = 130.4 mm; B = 175 mm; C = 300 mm; weight: 1260 g.<br \/>\nClamp operating frequency range: 256 Hz to 200 kHz.<br \/>\nClamp environmental ratings: IP54; operating temperature: \u221220\u00b0C to +50\u00b0C; storage temperature: \u221240\u00b0C to +70\u00b0C.<br \/>\nSafety (particularly important when working on utilities):<\/p>\n<p>When using the clamp on live utilities, minimise the risk of arcing or hazardous signals. Do not fit the clamp around cables with damaged or missing insulation. Before placing it around a cable, ensure that the clamp is securely connected to the port on the Leica DE100 signal transmitter.<br \/>\nFor best results, the cable should be earthed at both ends and the clamp jaws fully closed to maximise induced current. <\/p>\n<p><strong>Brief description:<\/strong> The Leica inductive clamp makes it easy to apply a signal from the DE100 transmitter to a selected cable without directly connecting crocodile-clip leads. It is particularly useful in congested cable routes and where access to a connection point is difficult.<\/p>\n<p><strong>Full technical description:<\/strong> A signal clamp for inductively coupling a locating signal onto a cable or utility. It can be used with the DE100 transmitter to apply a signal to a cable or, when connected to the DT100 locator, to identify the correct cable in a bundle. Designed for field use (IP54).<\/p>\n<p><strong>Compatibility:<\/strong> Leica DT100 \/ DE100 system (clamp for use with the DE100 and DT100).<\/p>\n<p><strong>Package contents:<\/strong> Inductive clamp with a 5 m connection cable. (Other items are not applicable or are not included with this product.)<\/p>\n<p><strong>Safety \/ operation instructions:<\/strong><\/p>\n<ul>\n<li>Before fitting the clamp around a cable, ensure that it is securely connected to the transmitter port.<\/li>\n<li>Do not fit clamps around cables with damaged or missing insulation.<\/li>\n<li>For best results, the conductor should be earthed at both ends and the clamp jaws fully closed.<\/li>\n<\/ul>\n<p><strong>Dimensions \/ mass:<\/strong> see the technical specifications table.<\/p>\n<p><strong>Operating \/ charging time:<\/strong> not applicable (passive accessory).<\/p>\n<p><strong>Warranty:<\/strong> in accordance with the Leica Geosystems International Limited Warranty (details depend on the country and the current version of the terms).<\/p>\n<p><strong>Compatible accessories (optional):<\/strong> DT Series crocodile-clip leads, DT Series earth lead reel, DT\/DE Series system bags, and Li-Ion batteries and chargers for DT100\/DE100.<\/p>\n<div class=\"bl-caption\">Technical specifications<\/div>\n<table class=\"bl-spec\">\n<tr>\n<th>Manufacturer<\/th>\n<td>Leica Geosystems<\/td>\n<\/tr>\n<tr>\n<th>Part number (Leica)<\/th>\n<td>1005583<\/td>\n<\/tr>\n<tr>\n<th>Type of accessory<\/th>\n<td>Multifrequency inductive signal clamp<\/td>\n<\/tr>\n<tr>\n<th>Cable length<\/th>\n<td>5 m<\/td>\n<\/tr>\n<tr>\n<th>Operating frequency range<\/th>\n<td>256 Hz \u2013 200 kHz<\/td>\n<\/tr>\n<tr>\n<th>Dimensions (A\u00d7B\u00d7C according to documentation)<\/th>\n<td>130.4 \u00d7 175 \u00d7 300 mm<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>1260 g<\/td>\n<\/tr>\n<tr>\n<th>Ingress protection rating<\/th>\n<td>IP54<\/td>\n<\/tr>\n<tr>\n<th>Operating temperature<\/th>\n<td>-20\u00b0C to +50\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Storage temperature<\/th>\n<td>-40\u00b0C to +70\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Compatibility<\/th>\n<td>Leica DE100, Leica DT100<\/td>\n<\/tr>\n<tr>\n<th>Remarks<\/th>\n<td>For optimum inductive signal coupling, ensure that the clamp jaws are fully closed and the conductor is earthed.<\/td>\n<\/tr>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Klema (cewka indukcyjna) jest przeznaczona do indukcyjnego generowania sygna\u0142u z nadajnika (generatora) DE100 w przewodzie\/kablu\/instalacji, gdy bezpo\u015brednie pod\u0142\u0105czenie zacidkami typu krokodyle\/galwanicznie jest utrudnione lub niemo\u017cliwe. W dokumentacji systemu opisano zar\u00f3wno u\u017cycie klemy jako \u201etransmitter clamp\u201d (do podania sygna\u0142u), jak i \u201elocator clamp\u201d (do identyfikacji konkretnego kabla w wi\u0105zce). Parametry Numer katalogowy (Leica): 1005583. D\u0142ugo\u015b\u0107 przewodu: [&hellip;]<\/p>\n","protected":false},"featured_media":4295,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[63],"product_cat":[73],"product_tag":[],"class_list":["post-4294","product","type-product","status-publish","has-post-thumbnail","product_brand-leica-geosystems","product_cat-akcesoria-do-wykrywaczy","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/sklep.geoscanners.pl\/en\/wp-json\/wp\/v2\/product\/4294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sklep.geoscanners.pl\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sklep.geoscanners.pl\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sklep.geoscanners.pl\/en\/wp-json\/wp\/v2\/comments?post=4294"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sklep.geoscanners.pl\/en\/wp-json\/wp\/v2\/media\/4295"}],"wp:attachment":[{"href":"https:\/\/sklep.geoscanners.pl\/en\/wp-json\/wp\/v2\/media?parent=4294"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/sklep.geoscanners.pl\/en\/wp-json\/wp\/v2\/product_brand?post=4294"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/sklep.geoscanners.pl\/en\/wp-json\/wp\/v2\/product_cat?post=4294"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/sklep.geoscanners.pl\/en\/wp-json\/wp\/v2\/product_tag?post=4294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}