🔍Leica DD175 cable locator
1 670 €Net price: 1 358 €
Leica DD175 cable and underground utility locator
Live cable detection, passive mode and compatibility with the DA175 signal transmitter and signal sondes
View the brochure and technical data (PDF)
- Over a decade of experience
- Professional training
- We work throughout the EU
- Professional after-sales support
- We offer premium products
Leica DD175 with data logging and Bluetooth
The Leica DD175 combines underground utility locating with data logging and Bluetooth connectivity. It suits teams that want the features of the DD100 series and a record of their work as part of their job workflow. A DA175 transmitter can be added for active line tracing. The locator and complete kits have separate product pages with their contents listed.
When should you choose the Leica DD175?
Choose the DD175 when you need data logging and Bluetooth connectivity with the DX Software Suite alongside tracing. If you do not need to record data, compare the DD130. If you are putting together a new system, see the DD175 + DA175 kit with connection leads and a carry bag.
Technical specifications
Comparison of DD100 series locator models
| Operating mode | DD120 | DD130 | DD175 |
|---|---|---|---|
| Power | Live cable detection — 50 Hz | ||
| Radio | Frequency range: 15 kHz – 60 kHz | ||
| Automatic | Power, Radio, 33 kHz | ||
| Signal transmitter | 8 kHz and 33 kHz | 512 Hz, 640 Hz, 8 kHz, 33 kHz | 512 Hz, 640 Hz, 8 kHz, 33 kHz |
| Sonde | 8 kHz and 33 kHz | 512 Hz, 640 Hz, 8 kHz, 33 kHz | 512 Hz, 640 Hz, 8 kHz, 33 kHz |
| Detection depth | Up to 3 m – Power, Transmitter Up to 3 m — sonde |
Up to 3 m – Power, Transmitter 0.1–9.99 m — sonde |
Up to 3 m – Power, Transmitter 0.1–9.99 m — sonde |
| Depth measurement accuracy | 10% of depth with an undistorted signal | ||
| Protection rating | IP54 protection rating | ||
| Operating temperature | from -20 °C to +50 °C | ||
| Batteries | 6 AA batteries (IEC LR6) | ||
| Battery life | 15 hours of continuous operation at 20 °C | ||
| Dimensions (HxWxD) | 760x250x85 mm | ||
| Weight | 2.7 kg – weight with batteries | ||
| Bluetooth ® | No | No | YES |
| GPS | No | No | YES |
LEICA DD175 OPERATING MODES
• Automatic mode (passive)
Automatically detects electrical or radio fields, allowing underground utilities to be located as soon as work begins and making cable detection faster.
• Radio mode (passive)
Detects radio noise – specifically, radio signals re-radiated by underground utilities that are energised by distant radio transmitters.
Radio waves penetrate the ground and energise underground utilities. The resulting signals can then be detected using the Leica DD175 cable locator.
• Power mode (default)
Detects signals generated by live power cables operating at 50 or 60 Hz, which pose a major hazard during excavation.
• Transmitter or sonde mode (active, 8 and 33 kHz)
It detects signals generated by the dual-frequency DA175 signal transmitter. In active mode, a signal at 8 or 33 kHz is applied to a conductor by induction or direct connection and then detected at the surface using the Leica DD175 locator. This enables the detection of de-energised cables, pipes and other metallic underground utilities.
Leica DD175 DD-series cable locator — advanced intelligence
Measuring the depth of underground utilities
Leica DD175 cable locators can estimate utility depth in active mode using a DA175 signal transmitter or a standard signal sonde at 8 or 33 kHz. At the press of a button, the user receives an approximate depth reading for the cable or line.
Peak reading
The maximum reading function allows you to accurately identify the wire or electric cable by displaying the maximum amplitude for a short time.
Improved sonde detection
DD175 cable locators in the DD series have a user-friendly display showing the received signal level. The peak signal reading indicates the position of the Digimouse sonde below ground.
Hazard zone
Shallowly buried cables pose a potentially fatal hazard to construction workers. The DD series includes a Danger Zone feature that provides an additional warning when the locator operator is close to a buried cable.
Compare related products
DD175 + DA175 kit · DD175 + DA175 kit with Digicat signal clamp · Leica DD130 · Leica DT100
Help choosing equipment
- Which cable and pipe locator should you choose? Leica DD120, DD130, DD175 or DT100
Choose a locator for the utility and working method. Compare Leica DD100 with DT100, transmitters, sondes and the equipment supplied in kits.
Brochures and technical data
Explore the equipment's capabilities and check its specifications and supplied equipment before choosing.
| Model | DD175 |
|---|---|
| Manufacturer | Leica Geosystems |
| Type | Cable locator |
| Operating modes | Power, Radio, Automatic |
| Active mode | Signal transmitter, sonde |
| Active locating frequencies | 8 kHz, 33 kHz |
| Passive frequencies | 15-60 kHz |
| Utility detection | Live power cables, 50/60 Hz |
| Detection depth | Up to 9 m |
| Depth accuracy | ±10% |
| Power supply | 6x AA |
| Battery life | About 15 hours |
| Weight | 2.7 kg |
| Dimensions | 760x250x85 mm |
| Protection rating | IP54 |
| Operating temperature | -20°C to +50°C |
| Display | Backlit LCD |
| Bluetooth | Yes |
| GPS | Yes |
| Peak hold function | Yes |
| Hazard warning | Hazard zone |