🔍Leica DD120 cable locator
1 310 €Net price: 1 065 €
Leica DD120 cable and underground utility locator
Live cable detection, passive mode and compatibility with the DA175 signal transmitter and signal sondes
View the brochure and technical data (PDF)
- Over a decade of experience
- Professional training
- We work throughout the EU
- Professional after-sales support
- We offer premium products
Leica DD120 for checks before excavation
The Leica DD120 is a straightforward locator for checking a site before excavation. Power, Radio and Auto modes let you begin a survey without a transmitter, while 8 and 33 kHz operation enables tracing with a suitable signal source. This offer covers the locator only; a transmitter is available separately or as part of a kit.
When should you choose the Leica DD120?
Choose the DD120 for basic site checks and tracing at 8 and 33 kHz. If you also need 512 and 640 Hz frequencies and signal current readings, compare the DD130. For active line tracing with a transmitter, see the DD120 + DA175 kit.
Technical specifications
Comparison of DD100 series locator models
| Operating mode | DD120 | DD130 | DD175 |
|---|---|---|---|
| Power | Live cable detection — 50 Hz | ||
| Radio | Frequency range: 15 kHz – 60 kHz | ||
| Automatic | Power, Radio, 33 kHz | ||
| Signal transmitter | 8 kHz and 33 kHz | 512 Hz, 640 Hz, 8 kHz, 33 kHz | 512 Hz, 640 Hz, 8 kHz, 33 kHz |
| Sonde | 8 kHz and 33 kHz | 512 Hz, 640 Hz, 8 kHz, 33 kHz | 512 Hz, 640 Hz, 8 kHz, 33 kHz |
| Detection depth | Up to 3 m – Power, Transmitter Up to 3 m — sonde |
Up to 3 m – Power, Transmitter 0.1–9.99 m — sonde |
Up to 3 m – Power, Transmitter 0.1–9.99 m — sonde |
| Depth measurement accuracy | 10% of depth with an undistorted signal | ||
| Protection rating | IP54 protection rating | ||
| Operating temperature | from -20 °C to +50 °C | ||
| Batteries | 6 AA batteries (IEC LR6) | ||
| Battery life | 15 hours of continuous operation at 20 °C | ||
| Dimensions (HxWxD) | 760x250x85 mm | ||
| Weight | 2.7 kg – weight with batteries | ||
| Bluetooth ® | No | No | YES |
| GPS | No | No | YES |
LEICA DD120 OPERATING MODES
• Automatic mode (passive)
Automatically detects electrical or radio fields, allowing underground utilities to be located as soon as work begins and making cable detection faster.
• Radio mode (passive)
Detects radio noise – specifically, radio signals re-radiated by underground utilities that are energised by distant radio transmitters.
Radio waves penetrate the ground and energise underground utilities. The resulting signals can then be detected using the Leica DD120 cable locator.
• Power mode (default)
Detects signals generated by live power cables operating at 50 or 60 Hz, which pose a major hazard during excavation.
• Transmitter or sonde mode (active, 8 and 33 kHz)
It detects signals generated by the dual-frequency DA175 signal transmitter. In active mode, a signal at 8 or 33 kHz is applied to a conductor by induction or direct connection and then detected at the surface using the Leica DD120 locator. This enables the detection of de-energised cables, pipes and other metallic underground utilities.
Leica DD120 DD-series cable locator — advanced intelligence
Measuring the depth of underground utilities
Leica DD120 cable locators can estimate utility depth in active mode using a DA175 signal transmitter or a standard signal sonde at 8 or 33 kHz. At the press of a button, the user receives an approximate depth reading for the cable or line.
Peak reading
The maximum reading function allows you to accurately identify the wire or electric cable by displaying the maximum amplitude for a short time.
Improved sonde detection
DD120 cable locators in the DD series have a user-friendly display showing the received signal level. The peak signal reading indicates the position of the Digimouse sonde below ground.
Hazard zone
Shallowly buried cables pose a potentially fatal hazard to construction workers. The DD series includes a Danger Zone feature that provides an additional warning when the locator operator is close to a buried cable.
Compare related products
DD120 + DA175 kit · DD120 + DA175 kit with Digicat signal clamp · Leica DD130
Help choosing equipment
- Which cable and pipe locator should you choose? Leica DD120, DD130, DD175 or DT100
Choose a locator for the utility and working method. Compare Leica DD100 with DT100, transmitters, sondes and the equipment supplied in kits.
Brochures and technical data
Explore the equipment's capabilities and check its specifications and supplied equipment before choosing.
| Model | DD120 |
|---|---|
| Manufacturer | Leica Geosystems |
| Type | Cable locator |
| Technology | Digital Signal Processing |
| Operating modes | Power, Radio, Auto |
| Frequencies | 8 kHz, 33 kHz |
| Detection depth | Up to 3 m |
| Depth accuracy | ±10% |
| Ingress protection rating | IP54 |
| Operating temperature | -20°C to +50°C |
| Power supply | 6x AA |
| Operating time | 15 hours |
| Weight | 2.7 kg |
| Dimensions | 760x250x85 mm |
| Bluetooth | None |
| GPS | None |


























tomasz –